Who should establish a responsibility system for the safety management responsibility of gun safety management

2 thoughts on “Who should establish a responsibility system for the safety management responsibility of gun safety management”

  1. I. General requirements
    (1) Management requirements
    (1) The gun -related unit shall set up a special gun (ammunition) library room to store storage and storage guns and ammunition. The maximum temperature inside the storage of guns (ammunition) is not higher than 30 ° C, and the suitable temperature should be controlled within the range of 5-20 ° C; the maximum relative humidity should not be more than 70%. The relative humidity should be controlled at 55%to 65% Within range.
    (2) The gun -related units shall arrange special personnel and double locks to manage guns (ammunition) library rooms. The authorization approval system for the laboratory of the gun (ammunition) should be established, and no one can enter without approval.
    (3) The gun -related units shall set up a monitoring center in the appropriate location of the barrel (ammunition) library in accordance with the principles of facilitating monitoring and rapid disposal, and install direct calls and post alarm phone numbers to implement closed management.
    (4) The gun -related unit shall establish a gun safety management responsibility system with legal representative or person in charge as the “first responsible person” to clarify the responsibilities of the first responsible person, the person in charge, and the person directly responsible. Liability for safety management.
    (5) The gun -related unit shall establish and improve the management system of the gun (ammunition) library room and the monitoring center, strictly implement the double lock management of the gun (ammunition) library room, the bomb receiving approval registration and safety inspection, the gun involved staff Management education and other system requirements.
    (6) The gun -related units shall establish and improve the emergency response plan for the safety risk of the storage room of the gun (ammunition), and clarify the division of responsibilities, disposal procedures, methods, and requirements.
    (7) The gun -related units should establish a sound management account, and record the personnel entry and exit rooms and guns (ammunition) to receive (refund) and quantitative changes in detail.
    (8) The safety prevention system of the gun -related unit should conduct regular maintenance inspections of the safety prevention system of the gun (ammunition) library, and conduct a comprehensive inspection in a timely manner to ensure the effective operation of the safety prevention system.
    (2) Requirements for physical defense
    (1) The architectural design design of the gun (ammunition) library room shall meet the requirements of GB50068-2001. class.
    (2) The gun (ammunition) library and the monitoring center using brick -concrete or reinforced concrete building structure shall meet the requirements of GB50003-2001, GB50010-2010. Body, masonry should be solid materials. At the same time, the thickness of the wall should meet the following requirements: A) The gun (ammunition) library room set below the ground, its six -sided wall should use reinforced concrete building structure, and the thickness of the wall should be not less than 240mm; On the first floor of the gun (ammunition) library, the ground should be made of steel concrete building structure, and the thickness should not be less than 240mm. It is not less than 180mm; C) The gun (ammunition) library library set above the ground is set to use brick -hybrid building structure and its wall is the outer wall of the building. The thickness should not be less than 240mm. Its thickness should not be less than 180mm; if the steel -concrete building structure is used and its wall is the outer wall of the building, its thickness should not be less than 180mm. The wall is the wall of the building, and its thickness should not be less than 120mm.
    The brick -hybrid or reinforced concrete building structure Wall thickness cannot reach
    (3) The gun (ammunition) library required for the required, and the special cabinet or safe for guns (ammunition) that meets relevant national standards should be used. Store guns and ammunition. When the barrier (ammunition) dedicated cabinet or safe is less than 340kg, it should be fixed with the reinforced concrete floor or physical wall in the way of hidden in the bolt.
    (4) The gun (ammunition) library of brick -hybrid or reinforced concrete building structures should not be lower than the level of the wall required by the middle required wall.
    (5) The gun (ammunition) indoors (ammunition) of the gun (ammunition) shall be placed in cabinets, frames, boxes, etc. The width of the in -room entry and exit and operating channels should not be less than 1.5m.
    (6) Guns (ammunition) library located on the first floor of the ground or building should not be equipped with windows, and a ventilation port can be set on the top of the library or a wall near the top. The diameter of the circular ventilation port must not be greater than 160mm; the length of the unilateral length of the rectangular ventilation port must not be greater than 150mm. The ventilation port should be installed with metal protection network.
    (7) The windows of the gun (ammunition) library and the monitoring center shall be installed with solid reinforced material protective fences. The diameter of the protective fence should not be less than 12mm. The protective fence should be installed in an internal hidden bolt. The diameter of the installation bolt should not be less than 10mm and the distance is not more than 250mm.
    (8) The monitoring center shall install a flat -opening full -closed anti -theft safety door that meets the GB17565-2007 Gate C requirements.
    (9) Guns (ammunition) library and monitoring centers shall adopt locks that meet the GA/T73-1994B standards or GA374-2001 requirements.
    (3) Technical defense requirements
    (1) The barrier of the gun (ammunition) shall be installed with an invasive alarm system: A) The invasion alarm system shall meet the relevant requirements of GB50394-2007; Cross detection of the indoor protection target of the gun (ammunition) library and the door, window (sunroof), ventilation outlet and other parts; C) The thickness of the wall of the gun (ammunition) library not meets
    (2) requirements, (2) requirements, (2) requirements, (2) requirements, The wall vibration alarm device should be installed; D) The invasive alarm information should be sent to the monitoring center and the defense duty room in an automatic manner. It can run independently, and can be flexibly programmed or withdrawn according to time, area, and location; it should have anti -destruction function, can automatically detect the operating status and signal transmission lines of the device, can issue a fault alarm and instruct the fault location in time; when there is an invasion When alarm, the alarm data of the alarm, address and related police conditions should be displayed and recorded; f) The invasion alarm system of the barrier (ammunition) library should be in a state of defense. During the work of the managers entering the gun (ammunition), the invasion of the alarm system can be temporarily withdrawn, and the temporary removal time does not exceed 4h.
    (3) Guns (ammunition) library room shall install video security monitoring system: A) Video security monitoring system should meet GB50395-2007, “Digital HD Video Monitoring System Technical Specification” (DB35/T1247), “Safety Prevention Prevention Prevention) Video monitoring network system information transmission, exchange, control technical requirements “(GB/T28181))